Lỗi máy photocopy Ricoh MP9001 - error code Ricoh MP9001
- Error Code: 182 Ricoh MP9001
- Description:Scanner Fan Error: Right Side
The fan located on the right side of the exposure unit is not rotating. - Causes:
- Check the fan connections
- Fan defective
- Check SBU connection
- SBU defective
- Remedy:
- Error Code: 185 Ricoh MP9001
- Description:CIS transmission error
Error caused during ASIC register's automatic initialization on the CIS, or during transmission between the CIS – DF. - Causes:
- Harness between the CIS – DF is disconnected
- CIS defective
- Remedy:
- Error Code: 186 Ricoh MP9001
- Description:CIS LED error
LED on the CIS causes error - During initializing, the ration of the average between leading-edge area and rearedge is beyond the permissible level (0.7 – 1.43).
- During scanning, the shading data peak is under 32(8bit).
- Causes:
- Harness CN210 and CN220 on ADF are disconnected.
- Otherwise, replace CIS.
- Remedy:
- Error Code: 187 Ricoh MP9001
- Description:CIS BK level error
The BK level scanned by CIS is abnormal. The BK level average of R, G or B is/are not from 2 to 62. 0 < Calibrated BK data level < 255(10bit). - Causes:
- Turn off the machine.
- Make sure CN210 and CN220 are connected firmly.
- Turn on the machine.
- Remedy:
- Error Code: 188 Ricoh MP9001
- Description:CIS white level error
The shading data peak detected from the CIS is abnormal. - Causes:
- CIS defective
- Remedy:
1. Make sure CN210 and CN220 are connected firmly.
2. Replace the CIS.
- Error Code: 189 Ricoh MP9001
- Description:CIS gray balance adjustment error
The adjustment error occurs during the test after adjusting the gray balance. - Causes:
- CIS defective
- Remedy:
1. Retry the gray balance adjustment.
2. If the machine does not recover, do the following steps.
• Turn off the machine.
• Make sure CN210 and CN220 are connected firmly.
• Turn on the machine.
3. If the machine does not recover, replace the CIS.
lỗi ricoh MP9001
Error Code:182 Ricoh MP9001
- Description:Scanner Fan Error: Right Side
The fan located on the right side of the exposure unit is not rotating. - Causes:
- Check the fan connections
- Fan defective
- Check SBU connection
- SBU defective
- Remedy:
- Error Code: 185 Ricoh MP9001
- Description:CIS transmission error
Error caused during ASIC register's automatic initialization on the CIS, or during transmission between the CIS – DF. - Causes:• Harness between the CIS – DF is disconnected • CIS defective
- Remedy:
lỗi máy photo ricoh
Lỗi SC 186 Ricoh MP9001
- Description:Đèn LED báo lỗi CIS
LED trên CIS gây ra lỗi
• Trong quá trình khởi tạo, tỷ lệ trung bình giữa diện tích cạnh hàng đầu và vùng nuôi vượt quá mức cho phép (0,7 - 1,43).
• Trong khi quét, đỉnh dữ liệu tô bóng dưới 32 (8bit).
• Khai thác CN210 và CN220 trên ADF bị ngắt kết nối.
• Nếu không, hãy thay thế CIS.
- Lỗi SC 187 Ricoh MP9001
- Sự miêu tả:Lỗi mức BK của CIS
Mức BK được quét bởi CIS là bất thường. Mức BK trung bình của R, G hoặc B không phải là từ 2 đến 62. 0 <Mức dữ liệu BK đã hiệu chỉnh <255 (10bit). - Nguyên nhân:
- Tắt máy.
- Đảm bảo CN210 và CN220 được kết nối chắc chắn.
- Bật máy.
- Biện pháp khắc phục:
- Lỗi SC 188 Ricoh MP9001
- Sự miêu tả:Lỗi mức trắng CIS
Đỉnh dữ liệu tô bóng được phát hiện từ CIS là bất thường. - Nguyên nhân:
- CIS bị lỗi
- Biện pháp khắc phục:
1. Đảm bảo CN210 và CN220 được kết nối chắc chắn.
2. Thay thế CIS.
- Lỗi SC189 Ricoh MP9001
- Sự miêu tả:Lỗi điều chỉnh cân bằng xám CIS Lỗi
điều chỉnh xảy ra trong quá trình thử nghiệm sau khi điều chỉnh cân bằng xám. - Nguyên nhân:
- CIS bị lỗi
- Biện pháp khắc phục:
1. Thử lại điều chỉnh cân bằng màu xám.
2. Nếu máy không phục hồi, hãy làm theo các bước sau.
• Tắt máy.
• Đảm bảo CN210 và CN220 được kết nối chắc chắn.
• Bật máy.
3. Nếu máy không phục hồi, hãy thay thế CIS.
Error code 195 Ricoh MP9001 - Lỗi SC195 Ricoh MP9001
- Description:Machine serial number error
The number registered for the machine serial number does not match. - Causes:
- Remedy:1. Confirm the correct serial number of the machine in the specifications. Important: When SC195 occurs, the serial number must be input. Contact your technical supervisor.
- Error code 202 Ricoh MP9001 - Lỗi SC202 Ricoh MP9001
- Description:Polygon mirror motor error 1: Timeout at ON
The polygon mirror motor unit did not enter "Ready" status within 20 sec. after the motor was turned on, - Causes:
- The polygon mirror motor PCB connector is loose, broken, or defective
- Polygon mirror motor PCB defective
- Polygon mirror motor defective
- IPU defective
- Remedy:
- Error code 203 Ricoh MP9001 - Lỗi SC203 Ricoh MP9001
- Description:Polygon mirror motor error 2: Timeout at OFF
The polygon mirror motor did not leave "Ready" within 3 sec. after the motor was switched off. (The XSCRDY signal did not go HIGH (inactive) within 3 sec.) - Causes:
- The polygon mirror motor PCB connector is loose, broken, or defective
- Polygon mirror motor PCB defective
- Polygon mirror motor defective
- IPU defective
- Remedy:
- Error Code: 204 Ricoh MP9001
- Description:Polygon mirror motor error 3: XSCRDY signal error
The polygon mirror motor "Ready" signal goes inactive (HIGH) while images are being produced or the synchronization signal is being output. - Causes:
- Polygon mirror motor PCB connector loose, broken, defective
- Polygon mirror motor PCB defective
- Polygon mirror motor defective
- Remedy:
- Error code Code: 205 Ricoh MP9001
- Description:Polygon mirror motor error 4: Unstable timeout
The "Ready" signal (XSCRDY) was detected as unstable for more than 20 sec. while the polygon mirror motor was operating at normal speed. - Causes:
- Electrical noise on the line with the motor signals
- Polygon mirror motor PCB connector loose, broken, defective
- Polygon mirror motor PCB defective
- IPU defective
- Remedy:
- Error Code: 220 Ricoh MP9001
- Description:Laser synchronization detection error
The 1st laser synchronization detection unit could not detect the line synchronization signal (DETP0) within 500 ms while the polygon mirror motor was operating at normal speed. Note: The unit polls for the signal every 50 ms. This SC is issued after the 10th attempt fails to detect the signal. - Causes:• Laser synchronization board connector loose, broken, defective • Laser synchronization detection board is not installed correctly (out of alignment) • Laser synchronization board defective • IPU defective
- Remedy:
Lỗi SC195 Ricoh MP9001
- Sự miêu tả:Lỗi số sê-ri máy
Số đã đăng ký cho số sê-ri máy không khớp. - Nguyên nhân:
- Biện pháp khắc phục:1. Xác nhận đúng số sê-ri của máy trong thông số kỹ thuật. Quan trọng: Khi SC195 xảy ra, phải nhập số sê-ri. Liên hệ với người giám sát kỹ thuật của bạn.
- Lỗi SC202 Ricoh MP9001
- Sự miêu tả:Lỗi động cơ gương đa giác 1: Hết thời gian ở chế độ BẬT
Đơn vị động cơ gương đa giác không vào trạng thái "Sẵn sàng" trong vòng 20 giây. sau khi động cơ được bật, - Nguyên nhân:
- Đầu nối PCB của động cơ gương đa giác bị lỏng, bị hỏng hoặc bị lỗi
- PCB của động cơ gương đa giác bị lỗi
- Động cơ gương đa giác bị lỗi
- IPU bị lỗi
- Biện pháp khắc phục:
- Lỗi SC203 Ricoh MP9001
- Sự miêu tả:
1.Lỗi động cơ gương đa giác
2: Hết thời gian ở chế độ TẮT
Động cơ gương đa giác không rời khỏi trạng thái "Sẵn sàng" trong vòng 3 giây. sau khi động cơ được tắt. (Tín hiệu XSCRDY không ở mức CAO (không hoạt động) trong vòng 3 giây.)
- Nguyên nhân:
- Đầu nối PCB của động cơ gương đa giác bị lỏng, bị hỏng hoặc bị lỗi
- PCB của động cơ gương đa giác bị lỗi
- Động cơ gương đa giác bị lỗi
- IPU bị lỗi
- Biện pháp khắc phục:
- Lỗi SC204 Ricoh MP9001
- Sự miêu tả:Lỗi động cơ gương đa giác 3: Lỗi tín hiệu XSCRDY Tín hiệu
"Sẵn sàng" của động cơ gương đa giác không hoạt động (CAO) trong khi hình ảnh đang được tạo hoặc tín hiệu đồng bộ hóa đang được xuất. - Nguyên nhân:
- Đầu nối PCB của động cơ gương đa giác lỏng lẻo, bị hỏng, bị lỗi
- Động cơ gương đa giác PCB bị lỗi
- Động cơ gương đa giác bị lỗi
- Biện pháp khắc phục:
- Lỗi SC205 Ricoh MP9001
- Sự miêu tả:Đa giác lỗi động cơ gương 4: Thời gian chờ không ổn định
Tín hiệu "Sẵn sàng" (XSCRDY) được phát hiện là không ổn định trong hơn 20 giây. trong khi động cơ gương đa giác đang hoạt động ở tốc độ bình thường. - Nguyên nhân:
- Tiếng ồn điện trên đường dây với tín hiệu động cơ
- Đầu nối PCB của động cơ gương đa giác lỏng lẻo, bị hỏng, bị lỗi
- Động cơ gương đa giác PCB bị lỗi
- IPU bị lỗi
- Biện pháp khắc phục:
- Lỗi SC220 Ricoh MP9001
- Sự miêu tả:Lỗi phát hiện đồng bộ hóa
laser Bộ phát hiện đồng bộ hóa laser thứ nhất không thể phát hiện tín hiệu đồng bộ hóa đường truyền (DETP0) trong vòng 500 ms khi động cơ gương đa giác đang hoạt động ở tốc độ bình thường. Lưu ý: Đơn vị sẽ thăm dò tín hiệu cứ sau 50 ms. SC này được cấp sau lần thử thứ 10 không phát hiện được tín hiệu. - Nguyên nhân:
- Đầu nối bảng đồng bộ hóa laser lỏng lẻo, bị hỏng, bị lỗi
- Bảng phát hiện đồng bộ hóa laser không được lắp đặt đúng cách (không căn chỉnh)
- Bảng đồng bộ hóa laser bị lỗi
- IPU bị lỗi
- Biện pháp khắc phục:
Lỗi photo ricoh
Tham gia chát nhóm zalo: link 1 - link 2
page: tại đây
facebook: tại đây
Xem thêm: tại đây