Code
|
Description
|
Causes
|
101
|
Exposure Lamp Error The scanner has scanned the white plate, but cannot detect the white level.
|
• Defective exposure lamp • Defective exposure lamp stabilizer • Defective exposure lamp connector • Unclean scanner mirror • Scanner mirror out of position • Defective SBU board • Defective SBU connector • Lens block out of position • Incorrect position or width of white plate scanning (* SP4-015)
|
120
|
Scanner home position error 1 The scanner home position sensor does not detect the scanner leaving the home position.
|
• Defective scanner home position sensor • Defective scanner drive motor • Defective scanner home position sensor connector • Defective scanner drive motor connector • Defective BICU board
|
121
|
Scanner home position error 2 The scanner home position sensor does not detect the scanner coming back to the home position.
|
• Defective scanner home position sensor • Defective scanner drive motor • Defective scanner home position sensor connector • Defective scanner drive motor connector • Defective BICU board
|
141
|
SBU black level correction error • The automatic SBU adjustment has failed to correct the black level three times at the pre-offset adjustment. • The automatic SBU adjustment has failed to correct the black level ten times at the PGA adjustment. • The automatic SBU adjustment has failed to correct the black level ten times at the offset adjustment.
|
• Defective SBU board
|
142
|
SBU white/black level correction error The automatic SBU adjustment has failed to correct the white level ten times at the PGA adjustment.
|
• Defective exposure lamp • Unclean white plate • Incorrect position or width of white plate scanning (* SP4-015) • Defective SBU board
|
144
|
Communication Error between BICU and SBU The BICU cannot correctly establish communication with the SBU.
|
• Loose connection of the flat cable between the BICU and the SBU • Defective flat cable between the BICU and the SBU • Defective BICU • Defective SBU
|
145
|
Automatic SBU adjustment error The white levels of the white plate and the white paper are extraordinarily different during the Scan Auto Adjustment (* SP4-428-001).
|
• Defective exposure lamp • Unclean white plate • Incorrect position or width of white plate scanning (* SP4-015) • Defective BICU board • Defective SBU board
|
193
|
Image transfer error Scanned images are not transferred to the controller memory within one minute.
|
• Defective BICU board • Defective controller board
|
198
|
Memory address error The BICU does not receive the memory address report from the controller within one minute.
|
• Inconsistency between the BICU firmware and the controller firmware • Defective BICU • Defective controller
|
302
|
Charge roller current leak The polling module detects a current leak of the charge roller.
|
• Defective charge roller • Defective high voltage supply board • Loose connection of the PCU
|
320
|
Polygonal mirror motor error The polygon mirror motor does not reach the operating speed within 10 seconds. Or, the polygon mirror motor remains out of the operating speed for 0.2 second after reaching the operating speed.
|
• Defective polygon mirror motor • Loose connection between the polygonal mirror motor and the BICU • Defective cable between the BICU and the polygon mirror motor • Defective BICU
|
321
|
No laser writing signal (F-GATE) error The poling module does not detect the laser writing signal (F-GATE) asserting after the laser crosses 5 mm from the start point on the drum surface.
|
• Defective BICU • Loose connection on the fax controller or the printer controller • Defective fax controller or printer controller
|
322
|
Laser synchronization error The main scan synchronization detector does not detect the laser signal for 0.5 second.
|
• Toner bottle not installed • Loose connection between the LD unit and the BICU • Defective cable between the BICU and LD unit • LD unit out of position • Defective LD unit • Defective BICU
|
390
|
TD sensor error The BICU detects the TD sensor outputting extraordinary voltage (less than 0.2 V or more than 4.0 V) 10 times consecutively.
|
• Defective TD sensor • Loose connection of the PCU
|
391
|
Development bias leak The polling module detects a current leak of the development bias.
|
• Loose connection of the PCU • Defective high voltage
supply board
|
|
|
392
|
Developer initialization error The ID sensor does not detect a correct pattern during developer initialization (* 2-214-001).
|
• Defective ID sensor • Insufficient developer • Defective drum operation • Defective development roller operation • Loose connection of the PCU • Insufficient voltage for the charge roller
|
|
401
|
Transfer roller leak error (positive electrode) The feedback voltage of the transfer roller is insufficient.
|
• Defective high voltage supply board • Loose connection of the PCU • Incorrect installation of the transfer unit or the separation unit • Defective transfer roller
|
|
402
|
Transfer roller leak error (negative electrode) The feedback voltage of the transfer roller is insufficient.
|
• Defective high voltage supply board • Loose connection of the PCU • Incorrect installation of the transfer unit or the separation unit • Defective transfer roller
|
|
500
|
Main motor error A main motor lock signal is not detected for more than 7 consecutive checks (700 ms) after the main motor starts to rotate, or the lock signal is not detected for more than 7 consecutive checks during rotation after the last signal.
|
- Too much load on the drive mechanism - Main motor defective
|
|
502
|
Tray 2 lift motor malfunction (Optional paper tray units) The paper lift sensor fails to activate twice continuously after the tray lift motor has been on for 18 seconds.
|
- Paper lift sensor defective - Tray lift motor defective - Too much load on the drive mechanism - Poor tray lift motor connection
|
|
503
|
Tray 3 lift motor malfunction (optional paper tray units) The paper lift sensor fails to activate twice continuously after the tray lift motor has been on for 18 seconds.
|
- Paper lift sensor defective - Tray lift motor defective - Too much load on the drive mechanism - Poor tray lift motor connection
|
|
504
|
Tray 4 lift motor malfunction (optional two-tray paper tray unit) The paper lift sensor fails to activate twice continuously after the tray lift motor has been on for 18 seconds.
|
- Paper lift sensor defective - Tray lift motor defective - Too much load on the drive mechanism - Poor tray lift motor connection
|
|
506
|
Paper feed motor lock (optional paper tray units) A motor lock signal is not detected for more than 1.5 s or the lock signal is not detected for more than 1.0 s during rotation.
|
- Paper feed motor defective - Too much load on the drive mechanism
|
|
541
|
Fusing thermistor open (center) The fusing temperature detected by the thermistor is below 71C and is not corrected after the main power switch is turned on.
|
- Fusing thermistor defective or out of position - Power supply board defective - Loose connectors
|
|
542
|
Fusing temperature warm-up error (center) The fusing temperature rises less than 7 degrees in 2 seconds, and this continues 5 times consecutively. The fusing temperature is not detected in 25 or 35 seconds.
|
- Fusing thermistor defective or out of position - Fusing lamp open - Power supply board defective
|
|
543
|
Fusing overheat error (center) The fusing temperature is over 230C for 1 second (detected by the thermistor).
|
- Fusing thermistor defective - Power supply board defective
|
|
544
|
Fusing overheat error (center) 2 The fusing temperature is over 250C for 1 second (detected by the fusing temperature monitor circuit).
|
- Fusing thermistor defective - Power supply board defective
|
|
545
|
Fusing lamp overheat error (center) After the fusing temperature reaches the target temperature, the fusing lamp does not turn off for 12 consecutive seconds.
|
- Fusing thermistor defective or out of position - Power supply board defective
|
|
546
|
Unstable fusing temperature (center) The fusing temperature varies 50C or more within 1 second, and this occurs 2 consecutive times.
|
- Thermistor defective or out of position - Power supply unit defective
|
|
547
|
Zero cross signal malfunction Zero cross signals are not detected within 5 seconds after the main power switch is turned on, or are not detected within 1 second after operation begins.
|
- Power supply board defective - BICU defective
|
|
551
|
Fusing thermistor open (rear) The fusing temperature detected by the thermistor is below 71C and is not corrected after the main power switch is turned on.
|
- Fusing thermistor defective or out of position - Power supply board defective - Loose connectors
|
|
552
|
Fusing temperature warm-up error (rear) The fusing temperature rises less than 7 degrees in 2 seconds, and this continues 5 times consecutively. The fusing temperature is not detected in 25 or 35 seconds.
|
- Fusing thermistor defective or out of position - Fusing lamp open - Power supply board defective
|
|
553
|
Fusing overheat error (rear) The fusing temperature is over 230C for 1 second (detected by the thermistor).
|
- Fusing thermistor defective - Power supply board defective
|
|
555
|
Fusing lamp overheat error (rear) After the fusing temperature reaches the target temperature, the fusing lamp does not turn off for 20 consecutive seconds.
|
- Fusing thermistor defective or out of position - Power supply board defective
|
|
556
|
Unstable fusing temperature (rear)The fusing temperature varies 50C or more within 1 second, and this occurs 2 consecutive times.
|
- Thermistor defective or out of position - Power supply unit defective
|
|
559
|
Jam error detected 3 times in succession - The exit sensor and the duplex sensor detect a paper jam 3 times in succession - This condition can occur when SP 1159 1 is set to ‘on’. The default is ‘off’.
|
Paper jams can occur for the following reasons - Dampness - Paper curl - Incorrect paper setting in the paper tray - Stripper pawls coming apart
|
|
590
|
Left exhaust fan motor error The CPU detects an exhaust fan lock signal for more than 5 seconds.
|
- Loose connection of the exhaust fan motor - Too much load on the motor drive
|
|
591
|
Rear exhaust fan motor error The CPU detects an exhaust fan lock signal for more than 5 seconds.
|
- Loose connection of the exhaust fan motor - Too much load on the motor drive
|
|
620
|
Communication error between BICU and ADF The BICU does not receive a response from the ADF main board for 4 seconds or more. The BICU receives a break signal from the ADF main board.
|
- Poor connection between the BICU and ADF main board (DF connector) - ADF main board defective - BICU defective
|
|
621
|
ADF connection error An incorrect ADF (an ADF for some other copier) is detected. (for Basic and GDI machines) An ADF (including the correct ADF) is installed while the copier is in the energy saver mode. (for GDI machine only)
|
- ADF incorrect (The ADF for B039/B040/B043 or B121/B122/B123 is installed on a B245/B268/B269/B276/B277.) - The connector of the ADF is removed while the machine is in the energy saver mode.
|
|
632
|
Accounting error 1 An error is detected during the communication with the MF accounting device.
|
- Accounting device defective - Loose connection
|
|
633
|
Accounting error 2 After communication is established with the MF accounting device, a brake signal is issued.
|
- Accounting device defective - Loose connection
|
|
634
|
Accounting RAM error An error is detected in the RAM that saves the information on the MF accounting.
|
- Accounting device defective
|
|
635
|
Accounting battery error An error is detected in the battery that is in the MF accounting device.
|
- Accounting device defective
|
|
670
|
Engine start error The engine-ready signal is not issued within 70 seconds after the switch is turned on.
|
- Engine board defective - Controller defectiv - Loose connection
|
|
Code
|
Description
|
Causes
|
|
692
|
Controller board communication abnormal Communication error between the printer part of the controller board and BICU.
|
- The connector is abnormal between the controller board and the BICU board.
|
|
694
|
Controller board communication abnormal Communication error between the scanner part of the controller board and BICU.
|
- The connector is abnormal between the controller board and the BICU board.
|
|
760
|
ADF gate abnormal 1 The ADF Gate signal line between the ADF main board and the BICU is disconnected.
|
- ADF main board defective - Input/output board defective - Poor connection (ADF Gate line) between the ADF main board and the BICU.
|
|
761
|
ADF gate abnormal 2 The FGATE signal is not issued from the ADF within 30 seconds after the ADF starts feeding.
|
- ADF connector defective - SBU board defective
|
|
762
|
ADF gate abnormal 3 The FGATE signal is not terminated by the ADF within 60 seconds after the ADF starts feeding.
|
- ADF connector defective - SBU board defective
|
|
800
|
Startup without video output end error Video transfer to the engine is started, but the engine did not issue a video transmission end command within the specified time.
|
- Controller board defective
|
|
804
|
Startup without video input end A video transmission was requested from the scanner, but the scanner did not issue a video transmission end command within the specified time.
|
- Controller board defective
|
|
818
|
Watchdog error The CPU does not access the watchdog register within a certain time.
|
- Controller board defective - Software malfunction - download controller firmware again
|
|
819
|
Kernel mismatch error Software bug
|
- Download controller firmware again
|
|
820
|
Self-Diagnostic Error: CPU The central processing unit returned an error during the self-diagnostic test.
|
- Controller board defective - Download controller firmware again
|
|
821
|
Self-Diagnostic Error: ASIC The ASIC returned an error during the selfdiagnostic test because the ASIC and CPU timer interrupts were compared and determined to be out of range.
|
- Controller board defective
|
|
823
|
Self-diagnostic Error: Network Interface The network interface board returned an error during the self-diagnostic test.
|
- Network interface board defective - Controller board defective
|
|
824
|
Self-diagnostic Error: NVRAM The resident non-volatile RAM returned an error during the self-diagnostic test.
|
- Replace the NVRAM on the controller board - Replace the controller board
|
|
826
|
Self-diagnostic Error: NVRAM/Optional NVRAM The NVRAM or optional NVRAM returned an error during the self-diagnostic test.
|
- Replace the NVRAM on the controller board
|
|
827
|
Self-diagnostic Error: RAM The resident RAM returned a verify error during the self-diagnostic test.
|
- Download controller firmware again
|
|
Code
|
Description
|
Causes
|
|
828
|
Self-diagnostic Error: ROM The resident read-only memory returned an error during the self-diagnostic test.
|
- Controller board defective - Download controller firmware again
|
|
829
|
Self-diagnostic Error: Optional RAM The optional RAM returned an error during the self-diagnostic test
|
- Replace the optional memory board - Controller board defective
|
|
838
|
Self-diagnostic Error: Clock Generator A verify error occurred when setting data was read from the clock generator via the I2C bus
|
- Replace the controller board
|
|
850
|
Network I/F Abnormal NIB interface error.
|
- NIB defective - Controller board defective
|
|
857
|
USB I/F Error USB interface error detected.
|
- Defective controller
|
|
900
|
Electrical total counter error The electrical total counter does not work properly.
|
- NVRAM on the GDI controller board defective
|
|
901
|
Mechanical total counter The mechanical total counter does not work properly.
|
- Mechanical total counter defective - BICU defective - Disconnected mechanical total counter
|
|
903
|
Engine total counter error The checksum of the total counter is not correct.
|
- NVRAM on the BICU defective
|
|
920
|
Printer error A fatal error is detected in the printer application program
|
- Printer application program defective - Hardware configuration incorrect (including memory shortage)
|
|
921
|
Printer font error Necessary font files are not found.
|
- Font file not installed
|
|
928
|
Memory error The machine detects a discrepancy in the write/read data during its write/read test (done at power off/on and at recovery from low power or night/off mode).
|
- Memory defective - BICU defective - Poor connection between BICU and memory
|
|
954
|
Printer application program error The printer status does not become ready when the printer application program is necessary for image processing.
|
- Application program defective
|
|
955
|
Image transfer error The controller is not able to transfer images when the engine needs them.
|
- Application program defective
|
|
964
|
Status error (laser optics housing unit) The optics-housing unit does not become ready within 17 seconds after the request.
|
- Software defective
|
|
981
|
NVRAM error The machine detects a discrepancy in the NVRAM write/read data when attempting to save actual data to the NVRAM (i.e. during actual use).
|
- NVRAM defective - Poor connection between BICU and NVRAM - NVRAM is not connected - BICU defective
|
|
982
|
Localization error The localization settings in the nonvolatile ROM and RAM are different
|
- First machine start after the NVRAM is replaced - Incorrect localization setting - NVRAM defective
|
|
984
|
Print image transfer error Print images are not transferred.
|
- Controller defective - BICU board defective - Poor connection between controller and BICU
|
|
990
|
Software performance error The software attempted to perform an unexpected operation
|
- Software defective - Internal parameter incorrect - Insufficient working memory - When this SC occurs, the file name, address, and data will be stored in NVRAM. This information can be checked by using SP 7403. Note the above data and the situation in which this SC occurs. Then report the data and conditions to your technical control center.
|
|
991
|
Software continuity error The software attempted to perform an unexpected operation. However, unlike SC990, the object of the error is continuity of the software.
|
- No operation required. This SC code does not appear on the panel, and is only logged.
|
|
992
|
Unexpected Software Error Software encountered an unexpected operation not defined under any SC code.
|
- Software defective - An error undetectable by any other SC code occurred
|
|
997
|
Application function selection error The application selected by a key press on operation panel does not start or ends abnormally.
|
- Download the firmware for the application that failed - An option required by the application (RAM board) is not installed
|
|
998
|
Application start error After power on, the application does not start within 60 s. (All applications neither start nor end normally.)
|
- Download controller firmware - Replace the controller board - An option required by the application (RAM board) is not installed
|
|
999
|
Program download error The download (program, print data, language data) from the IC card does not execute normally.
|
- Board installed incorrectly - BICU board defective - Controller board defective - IC card defective - NVRAM defective - Loss of power during downloading - Important Notes About SC999 - Primarily intended for operating in the download mode, logging is not performed with SC999. - If the machine loses power while downloading, or if for some other reason the download does not end normally, this could damage the controller board or the PCB targeted for the download and prevent subsequent downloading. If this problem occurs, the damaged PCB must be replaced.
|
|
|
|
|