Description:Error in temperature rising of the Fixing Assembly
Causes:The temperature of the Fixing Assembly did not reach a certain temperature within the specified period of time.
Remedy:1. Check the harness/connector connection between the Fixing Assembly and the DC Controller PCB. 2. Replace the Fixing Assembly. 3. Replace the DC Controller PCB.
Code: E001-0000
Description:Abnormal high temperature of the Fixing Assembly
Causes:It was detected that the temperature of the Fixing Assembly was abnormally high.
Remedy:1. Check the harness/connector connection between the Fixing Assembly and the DC Controller PCB. 2. Replace the Fixing Assembly. 3. Replace the DC Controller PCB.
Code: E003-0000
Description:Abnormal low temperature of the Fixing Assembly
Causes:It was detected that the temperature of the Fixing Assembly was abnormally low.
Remedy:1. Check the harness/connector connection between the Fixing Assembly and the DC Controller PCB. 2. Replace the Fixing Assembly. 3. Replace the DC Controller PCB.
Code: E004-0000
Description:Drive circuit error
Causes:The zero cross signal was not detected for the specified period of time or more.
Remedy:1. Check the harness/connector connection between the Fixing Assembly and the DC Controller PCB. 2. Replace the Fixing Assembly. 3. Replace the DC Controller PCB.
Code: E014-0000
Description:Error in startup of the Main Motor
Causes:Revolution of the Main Motor did not reach the specified value.
Remedy:1. Check the harness/connector connection between the Main Motor and the DC Controller PCB. 2. Replace the Main Motor. 3. Replace the DC Controller PCB.
Code: E014-0001
Description:Error in startup of the Main Motor
Causes:Revolution of the Main Motor was out of the specified range.
Remedy:1. Check the harness/connector connection between the Main Motor and the DC Controller PCB. 2. Replace the Main Motor. 3. Replace the DC Controller PCB.
Code: E015-0002
Description:Cassette 2 lift-up error
Causes:After lift-up of the Lifting Plate of the Cassette 1 started, ON status of the Paper Surface Sensor of the Cassette 1 was not detected within the specified period of time.
Remedy:1. Turn ON the power with the cassette of the Cassette Unit removed, insert the cassette, and then check the operation sound of the Lifter Motor. When there is operation sound of the Lifter Motor, check if the Lifting Plate has been lifted up. <When the Lifting Plate has been lifted up> 1. Check the harness/connector connection between the Cassette Driver PCB and the Paper Surface Sensor of the Cassette Unit. 2. Check the harness/connector connection between the Cassette Driver PCB and the Cassette Pickup Solenoid of the Cassette Unit. 3. Replace the Cassette Driver PCB. 4. Replace the DC Controller PCB. <When the Lifting Plate has not been lifted up> 1. Check the condition of the gear of the Cassette Unit (missing teeth, swing). 2. Replace the Drive Unit of the Cassette Unit. <When there is no operation sound of the motor> 1. Check the harness/connector connection between the Cassette Driver PCB and the Lifter Motor of the Cassette Unit. 2. Replace the Drive Unit of the Cassette Unit. 3. Replace the Cassette Driver PCB. 4. Replace the DC Controller PCB 4. Replace the DC Controller.
Code: E052-0000
Description:Duplex Feed Unit absent error
Causes:Connection of the Duplex Feed Unit was not correct.
Remedy:1. Replace the DC Controller PCB.
Code: E066-0000
Description:Environment Sensor error
Causes:When the Environment Sensor is judged to be in error
Remedy:1. Check the harness/connector connection between the Power supply switch PCB (Environment Sensor) and the DC Controller PCB. 2. Replace the Power supply switch PCB (Environment Sensor). 3. Replace the DC Controller PCB.
Code: E100-0000
Description:BD error
Causes:BD error
Remedy:1. Check the harness, Flat Cable, and connector connection between the Laser Scanner Unit and the DC Controller PCB. 2. Replace the Flat Cable. 3. Replace the Laser Scanner Unit. 4. Replace the DC Controller PCB.
Code: E110-0000
Description:Error in startup of the Scanner Motor
Causes:Scanner area error (error in the initial operation of the Scanner Motor)
Remedy:1. Check the harness/connector connection between the DC Controller PCB and the Laser Scanner Unit. 2. Check the harness/connector connection between the Relay PCB and the Laser Scanner Unit. 3. Replace the Laser Scanner Unit.
Code: E110-0001
Description:Scanner Motor rotation error
Causes:Scanner area error (Scanner Motor rotation error)
Remedy:1. Check the harness/connector connection between the DC Controller PCB and the Laser Scanner Unit. 2. Check the harness/connector connection between the Relay PCB and the Laser Scanner Unit. 3. Replace the Laser Scanner Unit.
Code: E196-0000
Description:DC Controller error
Causes:Update of the DC Controller failed. (RFU mode right after the startup)
Remedy:1. Replace the DC Controller PCB.
Code: E196-1000
Description:ROM writing/reading error (Main ROM 16MB)
Causes:Error in writing/reading of main program in the Main Controller PCB (Main ROM 16MB)
Remedy:1. Update the set of controller firmware. 2. Replace the Main Controller PCB.
Code: E196-2000
Description:ROM writing/reading error (ROM (2MB) for storing setting values)
Causes:Error in writing/reading of the setting values storage area in the Main Controller PCB (ROM (2MB) for storing setting values)
Remedy:1. Update the set of controller firmware. 2. Replace the Main Controller PCB.
Code: E196-3000
Description:ROM writing/reading error (eMMC)
Causes:Unable to read/write data from the eMMC. The eMMC failure occurred.
Remedy:1. Update the set of controller firmware. 2. Replace the Main Controller PCB.
Code: E196-3001
Description:ROM-ID mismatch (eMMC)
Causes:The eMMC has been replaced wrongly. The eMMC failure occurred.
Remedy:1. Update the set of controller firmware. 2. Replace the Main Controller PCB.
Remedy:1. Update the set of controller firmware. 2. Replace the Main Controller PCB.
Code: E354-0000 ... E355-0005
Description:System error
Causes:System error
Remedy:Contact the sales company.
Code: E744-0001
Description:Invalid combination of language file versions
Causes:Language file version was not matched with that of the main program.
Remedy:1. Update the set of controller firmware.
Code: E744-0002
Description:Language file error
Causes:The size of the language file exceeded the allowed size.
Remedy:1. Update the set of controller firmware.
Code: E744-1001
Description:Version mismatch between BOOTABLE and BOOTROM
Causes:Version of the main program and that of the start-up program were not matched.
Remedy:1. Update the set of controller firmware.
Code: E744-4000
Description:Engine ID error
Causes:An invalid engine connection was detected.
Remedy:1. Check the version of D-CON. 2. Update the D-CON. 3. Update the set of controller firmware. 4. Check the model code. (E744-4000 occurs also when the model code and the engine code are mismatched.)
Code: E744-5000
Description:Panel microcomputer error
Causes:Error in the Control Panel PCB (microcomputer).
Remedy:1. Check the harness/connector connection between the panel microcomputer and Main Controller PCB. 2. Update the set of panel microcomputer. 3. Update the set of controller firmware. 4. Replace the Main Controller PCB.
Code: E744-6000
Description:Error in communication with the Wireless LAN Board
Causes:Unable to communicate with the Wireless LAN PCB.
Remedy:1. Check the connection of the wireless LAN slot (SD-IO). 2. Update the set of controller firmware. 3. Replace the Main Controller PCB.
Code: E744-7000
Description:Backup microcomputer error
Causes:An error in the microcomputer which retains fax job information of the Main Controller PCB.
Remedy:1. Check the version of backup microcomputer, and upgrade the version. 2. Update the set of backup microcomputer. 3. Update the set of controller firmware. 4. Replace the Main Controller PCB.
Code: E746-0000
Description:Main Controller PCB error (others)
Causes:A communication error of the Main Controller PCB occurred (other than scan-related communication error).
Remedy:1. Update the set of controller firmware. 2. Replace the Main Controller PCB.
Code: E766-9000
Description:Scanner power state error
Causes:Error in power state of the Laser Scanner Unit (firmware-dependent)
Remedy:1. Install the set of controller firmware. 2. Replace the Laser Scanner Unit.
Code: E805-0001
Description:Fan Motor 1 error
Causes:The Main Fan fails to rotate at the specified rotation speed.
Remedy:1. Check the connection of the Main Fan. 2. Replace the Main Fan.